ap1b02w10s06 (was ATLAPix1_GradeA_16) |
W10 |
aH18 v1.05 |
board CERN, loading UNIGE |
2018/06 |
CERN-887-R-Q58 (NA ctrl room) |
✅ |
Non-conductive sticky tape gluing in Unige, wire-bonding looked poor overall, see captured images. M2 and SimpleISO wire-bonds are removed, Simple is working fine now, ATLASPIx80OhmthinLowerSimpleISO 
ATLASPIx80OhmthinLowerSimple 
ATLASPIx80OhmthinLowerTrigger 
ATLASPIx80OhmthinUpperSimple 
ATLASPIx80OhmthinUpperSimpleISO 
ATLASPIx80OhmthinUpperTrigger
|
ap1b02w23s10 (was ATLAPix1_GradeA_17) |
W23 |
aH18 v1.0 |
board CERN, loading UNIGE |
2018/06 |
CERN-887-R-Q58 (NA ctrl room) |
❓ |
Non-conductive sticky tape gluing in Unige, wire-bonding looked poor overall, see captured images. M2 and SimpleISO wire-bonds are removed, Simple is working fine now, ATLASPIx200OhmthinLowerSimpleISO 
ATLASPIx200OhmthinLowerSimple 
ATLASPIx200OhmthinLowerTrigger] 
ATLASPIx200OhmthinUpperSimple] 
ATLASPIx200OhmthinUpperSimpleISO] 
ATLASPIx200OhmthinUpperTrigger]
|
ap1b02w10s13 |
W10 |
aH18 v2.0 |
board CERN, loading UNIGE |
2018/06 |
1-1-015, CERN |
✅ |
Non-conductive sticky tape gluing in Unige, wire-bonding on Simple matrix only, bonding looks ok, still to be tested, thinned to 70 um. |
ap1b02w11s05 |
W11 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/08 |
161-01-006, CERN |
❌ |
Conductive epoxy gluing in Unige, wire-bonding on Simple matrix only, bonding looks ok, tested, thinned to 70 um. VSSA seemed not connected (production issue of W11 perhaps). Disposed
|
ap1b02w23s15 |
W23 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/08 |
Was at DESY (Feb'2019), taken back to CERN, but cannot be found anymore |
✅ |
Conductive epoxy gluing in Unige, wire-bonding on Simple matrix only, bonding looks ok, still to be tested, thinned to 100 um |
ap1b02w23s12 |
W23 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/08 |
UniGE |
✅ |
Conductive epoxy gluing in Unige, wire-bonding done on Simple matrix only, Functional, thinned to 100 um, used by CLICdp |
ap1b02w10s33 |
W10 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/10 |
1-1-015, CERN |
❌ |
Conductive epoxy gluing in Unige, wire-bonding done on Simple matrix only, Analog OK, No digital activity, thinned to 62 um |
ap1b02w10s32 |
W10 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/10 |
161-01-006, CERN |
✅ |
Conductive epoxy gluing in Unige, wire-bonding done on Simple matrix only, Functional, thinned to 62 um |
ap1b02w10s31 |
W10 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/10 |
Fermilab |
✅ |
Conductive epoxy gluing in Unige, wire-bonding done on Simple matrix only, Functional, thinned to 62 um |
ap1b02w10s30 |
W10 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/10 |
1-1-015, CERN |
✅ |
Conductive epoxy gluing in Unige, wire-bonding done on all three matrices, still to be tested, thinned to 62 um, Later Trigger and SimpleISO matrices bond ripped off, simple used at DESY |
ap1b02w23s09 |
W23 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/10 |
1-1-015, CERN |
✅ |
Conductive epoxy gluing in Unige, wire-bonding done on all three matrices, leakage current ~3um for -5V to -60V, BUSY_ASSERTED all the time, thinned to 100 um |
ap1b02w07s11 |
W07 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/11 |
1-1-015, CERN |
❌ |
Conductive epoxy gluing in Unige, Substrate resistivity 80 Ω.cm, wire-bonding done on simple matrix, bad, Digital not functional, thinned to ~100 um by OPTIM (~90 um at Silicon only), Die dimension is bit large, Placement has engineered with Kapton tape to isolate HV to GND |
ap1b02w06s14 |
W06 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/11 |
1-1-015, CERN |
✅ |
Conductive epoxy gluing in Unige, Substrate resistivity 20 Ω.cm, wire-bonding done on simple matrix, tested,OK, thinned to ~100 um by OPTIM (~90 um at Silicon only), Die dimension is bit large, Placement has engineered with Kapton tape to isolate HV to GND |
ap1b02w06s11 |
W06 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/11 |
161-01-006, CERN |
✅ |
Conductive epoxy gluing in Unige, Substrate resistivity 20 Ω.cm, wire-bonding done on simple matrix, Tested,OK, thinned to ~100 um by OPTIM (~90 um at Silicon only), Die dimension is bit large, Placement has engineered with Kapton tape to isolate HV to GND |
ap1b02w06s12 |
W06 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/11 |
1-1-015, CERN |
✅ |
Conductive epoxy gluing in Unige, Substrate resistivity 20 Ω.cm, wire-bonding done on simple matrix, tested,OK, thinned to ~100 um by OPTIM (~90 um at Silicon only), Die dimension is bit large, Placement has engineered with Kapton tape to isolate HV to GND, used at SPS and DESY |
ap1b02w23s13 |
W23 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/11 |
161-01-006, CERN |
✅ |
Conductive epoxy gluing in Unige, Substrate resistivity 200 Ω.cm, wire-bonding done on simple matrix, tested,OK, thinned to ~100 um by Heidelberg |
ap1b02w23s11 |
W23 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/11 |
1-1-015, CERN |
✅ |
Conductive epoxy gluing in Unige, Substrate resistivity 200 Ω.cm, wire-bonding done on simple matrix,tested,OK, thinned to ~100 um by Heidelberg, simple used at DESY |
ap1b02w23s22 |
W23 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/11 |
1-1-015, CERN |
✅ |
Conductive epoxy gluing in Unige, Substrate resistivity 200 Ω.cm, wire-bonding done on simple matrix, Tested,OK, thinned to ~100 um by Heidelberg, simple used at DESY, damaged after testbeam? |
ap1b02w23s23 |
W23 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/11 |
1-1-015, CERN |
❌ |
Conductive epoxy gluing in Unige, Substrate resistivity 200 Ω.cm, wire-bonding done on simple matrix, Problem with TS and shift register, thinned to ~100 um by Heidelberg |
ap1b02w23s21 |
W23 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/11 |
161-01-006, CERN |
✅ |
Conductive epoxy gluing in Unige, Substrate resistivity 200 Ω.cm, wire-bonding done on simple matrix, tested,OK, thinned to ~100 um by Heidelberg |
ap1b02w23s20 |
W23 |
aH18 v3.1 |
board CERN, loading UNIGE |
2018/11 |
1-1-015, CERN |
❌ |
Conductive epoxy gluing in Unige, Substrate resistivity 200 Ω.cm, wire-bonding done on simple matrix, bad, digital not functional, probably bad SR, thinned to ~100 um by Heidelberg |
ap1b02w23s16 |
W23 |
aH18 v3.2 (only sample on this board version!) |
board CERN, loading UNIGE |
2021/01 |
1-1-015, CERN |
✅ |
Conductive epoxy gluing at CERN bonding lab, Substrate resistivity 200 Ω.cm, wire-bonding done on simple matrix, thinned to ~100 um by Heidelberg, IV: ok, configuration: ok, noise: ok, source (Fe-55): ok |