Skip to content

GitLab

  • Menu
Projects Groups Snippets
  • Help
    • Help
    • Support
    • Community forum
    • Submit feedback
  • Sign in
  • CARA CARA
  • Project information
    • Project information
    • Activity
    • Labels
    • Members
  • Repository
    • Repository
    • Files
    • Commits
    • Branches
    • Tags
    • Contributors
    • Graph
    • Compare
    • Locked Files
  • Issues 51
    • Issues 51
    • List
    • Boards
    • Service Desk
    • Milestones
    • Iterations
  • Merge requests 7
    • Merge requests 7
  • CI/CD
    • CI/CD
    • Pipelines
    • Jobs
    • Schedules
  • Deployments
    • Deployments
    • Releases
  • Packages & Registries
    • Packages & Registries
    • Container Registry
  • Analytics
    • Analytics
    • Value stream
    • CI/CD
    • Code review
    • Issue
    • Repository
  • Activity
  • Graph
  • Create a new issue
  • Jobs
  • Commits
  • Issue Boards
Collapse sidebar
  • CARA
  • CARACARA
  • Merge requests
  • !263

Model upgraded into fully diameter-dependent model

  • Review changes

  • Download
  • Email patches
  • Plain diff
Merged Nicolas Mounet requested to merge feature/diameter_dependent_dynamics_and_deposition into feature/scientific_model_update Sep 22, 2021
  • Overview 11
  • Commits 3
  • Pipelines 2
  • Changes 2

The gravitational settling is now fully diameter dependent, as well as f_dep (fraction of virions deposited on the respiratory tract), using the formulas from the CARA paper (to be published). An evaporation factor (default value = 0.3) is also introduced in ConcentrationModel, reducing the size of the aerosols before applying the formulas.

Generally speaking, probability of infection is slightly decreased by the first, slightly increased by the second.

This completes the two remaining tasks of #184 (closed)

Edited Sep 22, 2021 by Nicolas Mounet
Assignee
Assign to
Reviewer
Request review from
Time tracking
Source branch: feature/diameter_dependent_dynamics_and_deposition