diff --git a/docs/operations/threshold-scan.md b/docs/operations/threshold-scan.md index 2f2b74f90dab6df32278602cb3bc73c40b00b278..0a10804455c4033c87510f59f948193cfd1f95a1 100644 --- a/docs/operations/threshold-scan.md +++ b/docs/operations/threshold-scan.md @@ -8,7 +8,7 @@ From the RCMS interface, click on "Connect". Open the [xDAQ](http://srv-s2g18-33-01.cms:20100/urn:xdaq-application:service=calibration) calibration suite. In case the calibration suite page was already opened before you clicked on "Connect" in RCMS, reload the page manually. -From the dropdown menu, select the calibration type "S-bit ARM DAC Scan", then set the number of iterations in the "Iterations" text box to 1 and leave all the other parameters to their default values. Click on "Apply settings". +From the dropdown menu, select the calibration type "S-bit rate scan", then set the number of iterations in the "Iterations" text box to 1 and leave all the other parameters to their default values. Click on "Apply settings". Go back to the RCMS interface, then follow these steps: 1. click on "Configure" and wait for all the subsystems to be in _Configured_ state; @@ -17,4 +17,6 @@ Go back to the RCMS interface, then follow these steps: Go back to the calibration suite in xDAQ, then click on "Run". +While the scan is ongoing, from the P5 DAQ machine check that the output files are being written to the subfolders `fed1467` and `fed1468` of the folder `/gemdata/runs/test/sBitRateScan/`. + ## Analyzing the threshold scan results