Replaces the existing reference timestamp (earliest hit on reference plane) by either the trigger timestamp (method 0) or the average track timestamp (method 1). For method 0 to work, a trigger timestamp has to be saved as SPIDR signal during data taking.
### Parameters
*`improvementMethod`: Determines which method to use. Trigger timestamp is 0, average track timestamp is 1. Default value is `1`.
*`signalSource`: Determines which detector plane carries the trigger signals. Only relevant for method 0. Default value is `"W0013_G02"`.
*`triggerLatency`: Adds a latency to the trigger timestamp and shifts time histogrammes back to zero. Default value is `0`.
*`improvement_method`: Determines which method to use. Trigger timestamp is 0, average track timestamp is 1. Default value is `1`.
*`signal_source`: Determines which detector plane carries the trigger signals. Only relevant for method 0. Default value is `"W0013_G02"`.
*`trigger_latency`: Adds a latency to the trigger timestamp and shifts time histogrammes back to zero. Default value is `0`.