BERT Timeout to be dynamic
In lpGBT line 1310, the timeout is not dynamically set depending on the meas_time based time. This should be changed as for every BER going above 32 M clock cycles we exceed the timeout.
In lpGBT line 1310, the timeout is not dynamically set depending on the meas_time based time. This should be changed as for every BER going above 32 M clock cycles we exceed the timeout.