Commit 420b631d authored by Mark Hodgkinson's avatar Mark Hodgkinson
Browse files

Remove test that runs out dated pflow config and its associated job options file.

parent b6cd7cc0
#!/bin/sh
#
# art-description: Athena runs Standard ESD reconstruction including FlowElements, which are not in the default run
# art-type: grid
# art-include master/Athena
# art-athena-mt: 8
# art-output: AOD.pool.root
# art-output: log_FE_validation.txt
export ATHENA_CORE_NUMBER=8 # set number of cores used in multithread to 8.
athena.py eflowRec/run_ESDStandardReco_FlowElements.py
rc1=$?
python eflowRec/validateFlowElements.py --f AOD.pool.root &> log_FE_validation.txt
rc2=$?
echo "art-result: ${rc1} ESDtoAOD_FE"
echo "art-result: ${rc2} AOD_readout"
#This file is to run standard reconstruction + Flow Elements on an ESD file (Primarily the Flow Element configuration)
from AthenaCommon.AthenaCommonFlags import athenaCommonFlags
athenaCommonFlags.FilesInput=["/cvmfs/atlas-nightlies.cern.ch/repo/data/data-art/RecExRecoTest/mc16_13TeV.361022.Pythia8EvtGen_A14NNPDF23LO_jetjet_JZ2W.recon.ESD.e3668_s3170_r10572_homeMade.pool.root"]
doDumpProperties=True
from RecExConfig.RecAlgsFlags import recAlgs
recAlgs.doEFlow.set_Value_and_Lock(True)
from eflowRec.eflowRecFlags import jobproperties
jobproperties.eflowRecFlags.useCalibHitTruth.set_Value_and_Lock(True)
#include FlowElement validation plots
jobproperties.eflowRecFlags.doFlowElementValidation.set_Value_and_Lock(True)
from RecExConfig.RecFlags import rec
rec.doTrigger.set_Value_and_Lock(False)
rec.doEgamma.set_Value_and_Lock(False)
rec.doMuon.set_Value_and_Lock(False)
rec.doTau.set_Value_and_Lock(False)
#change some calo flags
from CaloRec.CaloRecFlags import jobproperties
jobproperties.CaloRecFlags.Enabled.set_Value_and_Lock(True)
jobproperties.CaloRecFlags.doCaloCluster.set_Value_and_Lock(True)
jobproperties.CaloRecFlags.doEmCluster.set_Value_and_Lock(False)
jobproperties.CaloRecFlags.doCaloTopoCluster.set_Value_and_Lock(True)
#nothing to say on these
rec.doWriteTAG.set_Value_and_Lock(False)
rec.doTruth.set_Value_and_Lock(False)
rec.doAODCaloCells.set_Value_and_Lock(False)
#Turns off xAODRingSetConfWriter
rec.doCaloRinger.set_Value_and_Lock(False)
#Turn of TAG
rec.doWriteTAG.set_Value_and_Lock(False)
#disables VertexCnvAlg
from InDetRecExample.InDetJobProperties import jobproperties
jobproperties.InDetJobProperties.doxAOD.set_Value_and_Lock(False)
#Disables AllExecutedEvents
rec.doFileMetaData.set_Value_and_Lock(False)
include("LArConditionsCommon/LArIdMap_MC_jobOptions.py")
from CaloRec import CaloClusterTopoCoolFolder
from CaloTools.CaloNoiseCondAlg import CaloNoiseCondAlg
CaloNoiseCondAlg()
CaloNoiseCondAlg(noisetype="electronicNoise")
athenaCommonFlags.EvtMax=30
#Run pflopw jet finding - this cannot be enabled via reconstruction flags currently! (without enabling other things we don't want)
UserAlgs = ["eflowRec/jetAlgs.py"]
include ("RecExCommon/RecExCommon_topOptions.py")
ServiceMgr.MessageSvc.defaultLimit = 9999999
include ("METReconstruction/METReconstruction_jobOptions.py")