From 90b360a999fb9c46739872a351d8568b4bc0bb42 Mon Sep 17 00:00:00 2001
From: =?UTF-8?q?Nicolas=20K=C3=B6hler?= <nicolas.koehler@cern.ch>
Date: Mon, 4 Jan 2021 14:02:42 +0100
Subject: [PATCH] fix input Trk::SegmentCollection name when running on old
 ESDs

---
 MuonSpectrometer/MuonConfig/python/MuonTrackBuildingConfig.py | 4 ++++
 1 file changed, 4 insertions(+)

diff --git a/MuonSpectrometer/MuonConfig/python/MuonTrackBuildingConfig.py b/MuonSpectrometer/MuonConfig/python/MuonTrackBuildingConfig.py
index 3036fb462f0..812e254a6e5 100644
--- a/MuonSpectrometer/MuonConfig/python/MuonTrackBuildingConfig.py
+++ b/MuonSpectrometer/MuonConfig/python/MuonTrackBuildingConfig.py
@@ -526,6 +526,10 @@ def MuonTrackBuildingCfg(flags, name = "MuPatTrackBuilder"):
     acc = MuonTrackSteeringCfg(flags)
     track_steering = acc.getPrimary()
     result.merge(acc)
+
+    # release 21 ESDs contain a Trk::SegmentCollection named 'MuonSegments' instead of 'TrackMuonSegments', the following 2 lines account for that
+    from MuonConfig.MuonSegmentNameFixConfig import MuonSegmentNameFixCfg
+    result.merge(MuonSegmentNameFixCfg(flags))
     
     track_builder = MuPatTrackBuilder(name=name, TrackSteering = track_steering, MuonSegmentCollection="TrackMuonSegments", SpectrometerTrackOutputLocation="MuonSpectrometerTracks" )
 
-- 