Fix maximum number of strips for LM2 and SM2 NSW micromega chambers
Hi,
it was found the the maximum number of strips in the LM2 and SM2 chambers of the NSW does not match the real number (cf. https://indico.cern.ch/event/786004/contributions/3465724/attachments/1861831/3060135/softwaremeeting130619.pdf). This MR fixes the maximum number to 3072 for the symmetric and asymmetric NSW layouts.
Adding @rosati, @wleight and @cchau for muon software Adding @ckitsaki who found the issue
Merge request reports
Activity
added alsoTargeting:21.3 alsoTargeting:21.9 labels
added Geometry master review-pending-level-1 labels
CI Result SUCCESSAthena AthSimulation externals cmake make required tests optional tests Full details available at NICOS MR-24170-2019-06-13-17-58
Athena: number of compilation errors 0, warnings 0
AthSimulation: number of compilation errors 0, warnings 0
For experts only: Jenkins output [CI-MERGE-REQUEST-CC7 325]added review-approved label and removed review-pending-level-1 label
mentioned in commit c0882895
added sweep:done label
mentioned in commit 17e8ad72
mentioned in merge request !24230 (merged)
mentioned in commit 596fd083
Sweep summary
successful:- 21.3
- 21.9
(see https://aiatlas154.cern.ch/jenkins/job/auto_git_sweeps/815/console for details)
mentioned in merge request !24231 (merged)
mentioned in commit 179ff79a
mentioned in commit 4ba4dd06
mentioned in merge request !26017 (merged)
mentioned in commit e5917b77