Tighten tau thinning in DAOD_PHYS/LITE
Hello,
This MR tightens the tau thinning and tau track thinning requirements in DAOD_PHYS/LITE. Instead of keeping taus with [0-5] tracks, we now require [1-3] tracks. This keeps 2p candidates which are used by some analyses, but discards 0p or 4p-5p taus, which were kept before but would likely never be used in analysis.
The size gain has been estimated from the ART tests:
Data before: 17161 taus, 33970 tau tracks
Disk Size Fraction Category Name
1.245 kb 0.053 tau
2.103 kb 0.089 InDet
23.646 kb 1.000 Total
Data after: 11684 taus, 20799 tau tracks
0.996 kb 0.043 tau
1.953 kb 0.084 InDet
23.234 kb 1.000 Total
ttbar MC before: 58919 taus, 125087 tau tracks
1.698 kb 0.042 tau
2.894 kb 0.071 InDet
40.483 kb 1.000 Total
ttbar MC after: 41225 taus, 74472 tau tracks
1.382 kb 0.034 tau
2.666 kb 0.066 InDet
40.098 kb 1.000 Total
Here, "tau" gathers taus and low-pt/high-pt ditaus. The change in thinning is applied to taus only.
Cheers, Bertrand
Edited by Bertrand Martin Dit Latour