Skip to content

xAODTau: drop range check on eta and phi

Hello,

This MR is dropping a range check on tau eta and phi that was introduced because we used to set dummy default values (-1111) for eta and phi for 0-prong and >5-prong taus, leading to eta = NAN upon retrieval. This has been fixed in the reconstruction (ATLTAU-1665), where we no longer set dummy values. So we can now drop the range check in the TauJet interface class, to save a tiny amount of CPU. This MR does not change the reconstruction output.

Cheers, Bertrand

Edited by Bertrand Martin Dit Latour