Draft: Expand the Magnetic field test so as to cover recent FPE issues
Ping
@schaffer and @jmaurer . This shows the "0,0,0" that causes the FPEs when Toroid off.
Note since we statically link to Geant4
one needs to have these
+ MagneticField/MagFieldUtils
+ Simulation/AtlasGeant4
+ MagneticField/MagFieldServices
+ Simulation/ISF/ISF_FastCaloSim/ISF_FastCaloSimParametrization
ping @jchapman
The issue is
MagFieldCondReader 1 0 INFO Field xyz: -161.341, 1063.34, 2171.6, -5.7681e-05, 0.000373872, 0.00168503
if all on
then
MagFieldCondReader 8 0 INFO Field xyz: -161.341, 1063.34, 2171.6, -0, 0, 0
when toroid off .
This is what I am failing to parse 100%.
Feel free to ping other Magnetic Field experts. Not sure if the code is buggy or the map or a combination, or really should be 0 there?