Fix dE/dx track and hit-based displaced vertex trigger: ATR-28087
Incorrect GeV to MeV conversion broke the dE/dx trigger. The counts went to 0 in the LLP grid test on 07-25 due to !64436 (merged).
Correcting this reverses the following count changes:
2711,2716c2711,2716
< HLT_xe80_tcpufit_dedxtrk25_medium_L1XE50 8
< HLT_xe80_tcpufit_dedxtrk25_medium_L1XE55 8
< HLT_xe80_tcpufit_dedxtrk25_medium_L1jXE100 8
< HLT_xe80_tcpufit_dedxtrk50_medium_L1XE50 7
< HLT_xe80_tcpufit_dedxtrk50_medium_L1XE55 7
< HLT_xe80_tcpufit_dedxtrk50_medium_L1jXE100 7
---
> HLT_xe80_tcpufit_dedxtrk25_medium_L1XE50 0
> HLT_xe80_tcpufit_dedxtrk25_medium_L1XE55 0
> HLT_xe80_tcpufit_dedxtrk25_medium_L1jXE100 0
> HLT_xe80_tcpufit_dedxtrk50_medium_L1XE50 0
> HLT_xe80_tcpufit_dedxtrk50_medium_L1XE55 0
> HLT_xe80_tcpufit_dedxtrk50_medium_L1jXE100 0
The other fix is for a simultaneous bug in the hit-based displaced vertex trigger, which raised the track pt cut from 0.5 GeV to 3 GeV, with the intended result:
< HLT_hitdvjet200_medium_L1XE50 9
< HLT_hitdvjet200_medium_L1XE55 9
< HLT_hitdvjet200_medium_L1jXE100 7
< HLT_hitdvjet260_medium_L1J100 3
< HLT_hitdvjet260_medium_L1jJ160 3
---
> HLT_hitdvjet200_medium_L1XE50 12
> HLT_hitdvjet200_medium_L1XE55 11
> HLT_hitdvjet200_medium_L1jXE100 11
> HLT_hitdvjet260_medium_L1J100 5
> HLT_hitdvjet260_medium_L1jJ160 5
1205,1208c1205,1208
< HLT_j180_hitdvjet200_medium_L1XE50 9
< HLT_j180_hitdvjet200_medium_L1XE55 9
< HLT_j180_hitdvjet260_medium_L1J100 3
< HLT_j180_hitdvjet260_medium_L1jJ160 3
---
> HLT_j180_hitdvjet200_medium_L1XE50 12
> HLT_j180_hitdvjet200_medium_L1XE55 11
> HLT_j180_hitdvjet260_medium_L1J100 5
> HLT_j180_hitdvjet260_medium_L1jJ160 5
I incidentally fixed an erroneous unordered_map
declaration, which isn't needed here.
Edited by Teng Jian Khoo