Mdt conditions remove string payload & add DCS voltages
MdtCondDbData:
- Noisy channels & chamber names are nowhere used. Remove them from as data members.
- Streamline the definition of what's a good chamber, layer, multilayer / tube .
- Add the DcsFsmState values to the conditions ojbect instead. They'll be used in the
MdtCalibDbAlg
MdtDigitization : Enforce the usage of the MdtCondDbData object to define dead channels
MdtCondJsonDumpAlg: Add algorithm to dump the constants into a JSON file. The dead channel data is dumped into different vectors where each entry is a composition of the Identifier fields:
{
"Chambers": [
{
"station": "BIL",
"eta": -6,
"phi": 1
}
],
"MultiLayers": [
{
"station": "BIL",
"eta": -6,
"phi": 1,
"ml": 1,
}
],
"TubeLayers:": [
{
"station": "BIL",
"eta": -6,
"phi": 1,
"ml": 1,
"layer": 1,
}
],
"Tubes:": [
{
"station": "BIL",
"eta": -6,
"phi": 1,
"ml": 1,
"layer": 1,
"tube": 1,
}
]
}
The DCS voltage data is dumped in the following format:
[
{
"station": "BIL",
"eta": -6,
"phi": 1,
"ml": 1,
"state": "ON",
"standByVolt": 2501,
"readyVolt": 3080
}, ...
]
This format is just a proposal. But I think, it's worth to reconsider how the data is processed on a longer term scale. Tagging: @formica, @zyan, @idrivask, @ekarentz