Split PFlow Weights Up
Currently WeightPFOTool returns one weight that is applied to FlowElements prior to jet finding. This weight consists of a part related to double counting of energy in the ID and calorimeter in eflowRec and one part related to smoothing out the uncalibrated jet energy scale.
This MR splits access to the weight into two parts which gives a clear separation between weights relevant at the individual FlowElement level and at the jet level.
No changes in output were expected. This was seen to be the case running diff-root on 500 WPrime events.
Merge request reports
Activity
CI Result SUCCESS (hash d3aff3d7)Athena AnalysisBase AthAnalysis externals cmake make tests Full details available on this CI monitor view. Check the JIRA CI status board for known problems
Athena: number of compilation errors 0, warnings 0
AnalysisBase: number of compilation errors 0, warnings 0
AthAnalysis: number of compilation errors 0, warnings 0
For experts only: Jenkins output (remote access info)removed review-pending-level-1 label
added review-approved label
added analysis-review-approved label and removed analysis-review-required label
mentioned in commit 1697b3cc