fix invertCMDin and invertCMDout settings
This MR removes the zturn_adapter
parameter in config file and adds invertCMDin
and invertCMDout
into config file for PBv3TBMassive20210504
.
The reason for this change is that ZTurn worker 3 needs CMDout inverted and other workers do not.
Set invertCMDin
to be true in config for ZTurn all workers
Set invertCMDou
t to be true in config for ZTurn worker 3; and false for worker 0,1,2,4
Example for worker 3:
"default": {
"type": "PBv3TBMassive20210504",
"i2cdev": "/dev/i2c-3",
"pbdev": "/dev/uio3",
"hvmuxdev": "/dev/spidev4.0",
"invertCMDin": true,
"invertCMDout": true
},
Example for other workers:
"default": {
"type": "PBv3TBMassive20210504",
"i2cdev": "/dev/i2c-1",
"pbdev": "/dev/uio1",
"hvmuxdev": "/dev/spidev2.0",
"invertCMDin": true,
"invertCMDout": false
},
Edited by Karol Krizka