Finalize temperature tests
PBV3TestTools::temperature
Checks temperature at a fixed setting optimized for room temperature. Note that only the NTCx,y are connected to a fixed input (10k resistor) on the test system. The other inputs measure actual temperatures and thus the results can vary based on the environment. Especially the NTCpb/PTAT values that measure the DC/DC converter temperature. They will be "hot" if run right after a test that enables it.
The following thresholds are applied to determined pass.
Input | Min | Max |
---|---|---|
CTAT | 300 | 400 |
PTAT | 350 | 450 |
NTCpb | 700 | 1000 |
NTCx | 600 | 700 |
NTCy | 600 | 700 |
Runs as part of basic tests.
PBV3TestTools::temperatureCTAT
and PBV3TestTools::temperatureNTC
Scans the NTC and CTAT settings in the AMAC. Measures the temperatures at each point.
Run as part of advanced tests.