DAQ lpGBT ADC7 temperature sensor uses current source now
Needs to be fixed: https://lpgbt.web.cern.ch/lpgbt/v1/analog.html#current-sources.
Thermistors have changed https://www.digikey.com/en/products/detail/tdk-corporation/NTCG063UH103HTBX/8565486 --> https://www.digikey.com/en/products/detail/tdk-corporation/NTCG063JF103FTB/5872743 , check that this is propagated in the code.