Skip to content

GBT sync FIFO updates | self trigger | X2O scripts | APEX updates for QC8 | CVP13 ME0 3 layers on single SLR

Evaldas Juska requested to merge top-ui-dev into devel
  • GBT sync FIFO now only starts reading when it becomes not empty after reset, and also writing and reading are delayed until rst busy signals clear
  • Self trigger option: triggers on any valid cluster from unmasked OHs when enabled. Individual VFAT mask can be controlled with the OH registers
  • X2O refclk monitoring script
  • X2O optics script
  • APEX updates for QC8 (increased OH count, added TTC TX, 10GbE LDAQ
  • CVP13 ME0 updated to have 3 layers (one full layer and two half-layers), this was done with a single SLR for software reasons, but this required pipelining MGT data path to cross SLRs, which should be undone asap
Edited by Evaldas Juska

Merge request reports