Allow zero magnetic field strength
Needed to run with zero magnetic field strength (otherwise the signed relevative current is a NaN
).
Validated by
-
Core Software -
RTA -
Simulation
Merge request reports
Activity
added RTA label
mentioned in merge request Moore!3582 (merged)
mentioned in merge request Alignment!527 (merged)
changed milestone to %RTA/2024.08.12-AugMD
- [2024-07-01 17:18] Validation started with lhcb-2024-patches-mr#925
- [2024-07-09 02:40] Validation started with lhcb-2024-patches-mr#982
Edited by Software for LHCb- Resolved by Maarten Van Veghel
- Resolved by Maarten Van Veghel
See https://lhcb-nightlies.web.cern.ch/nightly/lhcb-2024-patches-mr/925/Alignment/x86_64_v2-el9-gcc13-opt/tests#AlignTrTools_hlt2_reco_for_alignment_magnet_off for the results. Both matching and forward (latter using magnetic field) working now for long, UT hits added properly (also using magnetic field). Scale factor set to 0 of the magnetic field (as printed in the output). Hence approved from RTA side.
mentioned in commit MooreOnline@845c6109
- Resolved by Maarten Van Veghel
Hi @mveghel, could you please rebase this request, then we can merge it.
added 3 commits
-
a27604f2...4067e83c - 2 commits from branch
2024-patches
- 3bd8d542 - fix for zero magnetic field
-
a27604f2...4067e83c - 2 commits from branch
- Resolved by Menglin Xu
/ci-test
added ci-test-triggered label