Automatic derivation of sensor lookup table in UT
- replace hard-coded lookup table with derivation
- bring back sensor-swaps for old databases (addresses: #305 (closed))
- simplify a few things
Merge request reports
Activity
added RTA label
- Resolved by Michel De Cian
added 20 commits
-
390ec4a7...fac15526 - 10 commits from branch
master
- 24c0439b - predefine and move some numbers related to UT detector (readout) to UTInfo,...
- cdde7bc9 - rename constants to be more descriptive
- 7ab193c7 - more cleanup of unused code, some simplifications
- cc1b69e2 - simplify and make more clear
- c7c4a3d6 - replace hard-coded lookup table with derivation, bring back sensor-swaps for...
- f3cf7fa8 - remove const
- a089cdc1 - Fixed formatting
- a6e627c9 - replace hardcoded number with derived number from UTInfo::DetectorNumbers
- 856b2e16 - reverse logic of 'swapped'
- 089fa3fd - format
Toggle commit list-
390ec4a7...fac15526 - 10 commits from branch
added 1 commit
- 542cbea9 - add static sanity check, name a magic number
assigned to @mzdybal
- Resolved by Michel De Cian
@mzdybal This is ready for testing
added ci-test-triggered label
- [2023-05-31 14:51] Validation started with lhcb-master-mr#8085
- [2023-06-01 13:49] Validation started with lhcb-master-mr#8101
Edited by Software for LHCbadded hlt1-throughput-decreased label
- Resolved by Michel De Cian
- Resolved by Michel De Cian
- Resolved by Sebastien Ponce
Let's do a paranoia test on one platform after the style changes.
/ci-test --platforms=x86_64_v3-centos7-gcc11+detdesc-opt+g