Retuning of cut-based inclusive dilepton trigger
MR for the retuning of the cut-based inclusive dilepton trigger, as documented in #670 (closed), motivated in the talk in RTA WP3, 13th Nov 2023.
To-do:
-
Move builders to standard builders -
Reimplement fake PID lines -
Remove F.SIZE(pvs) > 0
workaround (MooreAnalysis#36 (moved)) -
Remove deprecated (original) lines -
Update docstrings -
Tune new lines -
Redefine prescales
Performance on 2024 MC
The efficiencies and rates of the retuned line are posted below for reference. All results were produced from MC with expected-2024 conditions, applying HLT1 directly as either hlt1_pp_forward_then_matching
or hlt1_pp_forward_then_matching_no_ut
.
Efficiencies
The following efficiencies are intended as a broader illustration of performance, by considering a few channels of interest for which 2024 conditions are available. All efficiencies are given with a HLT1 filtered denominator.
No UT
Channel | Cut-based efficiency (master) / % | Cut-based efficiency (retuned) / % | MVA-based efficiency (master) / % |
---|---|---|---|
B+ -> (J/psi -> e+ e-) K+ | 16.6 +/- 2.1 | 36.1 +/- 2.7 | 55.0 +/- 2.8 |
B+ -> (J/psi -> mu+ mu-) K+ | 17.2 +/- 2.3 | 26.7 +/- 2.7 | 44.3 +/- 3.1 |
Bs0 -> mu+ mu- | 30.3 +/- 3.7 | 45.2 +/- 4.0 | 61.9 +/- 3.9 |
Bs0 -> e+ e- | 30.0 +/- 3.9 | 36.4 +/- 4.1 | 52.1 +/- 4.2 |
Bs0 -> (J/psi -> mu+ mu-) (Phi -> K+ K-) | 12.7 +/- 1.9 | 32.1 +/- 2.7 | 52.9 +/- 2.8 |
Lb0 -> (Jpsi -> mu+ mu-) p+ K- | 13.2 +/- 1.9 | 30.1 +/- 2.6 | 49.8 +/- 2.8 |
Incl. J/psi -> mu+ mu- | 3.1 +/- 1.0 | 8.8 +/- 1.7 | 13.9 +/- 2.0 |
tau -> mu+ mu- mu+ | 12.4 +/- 2.0 | 43.5 +/- 3.0 | 56.2 +/- 3.0 |
With UT
Efficiencies are effectively consistent with "no UT" scenario, table available upon request.
Rates
Rates calculated with HltEfficiencyChecker on 2.5 mn events of 2024 minbias MC. HLT1 was applied directly with the sequences "hlt1_pp_forward_then_matching_no_ut" and "hlt1_pp_forward_then_matching", with rates then calculated based on a 30 MHz input rate. The inclusive rate of the cut-based dilepton trigger in master and in this MR (and relevant triggers in master) are quoted below:
Name | HLT2 rate (no UT) / kHz | HLT2 rate (with UT) / kHz |
---|---|---|
Total HLT1 | 9119 +/- 13 | 8435 +/- 12 |
Master cut-based dilepton trigger (real lines) | 0.333 +/- 0.092 | 0.333 +/- 0.092 |
!2747 (merged) cut-based dilepton trigger (real lines) | 4.44 +/- 0.34 | 4.28 +/- 0.12 |
!2747 (merged) cut-based dilepton trigger (single fake lines) | 0.59 +/- 0.12 | 0.59 +/- 0.12 |
!2747 (merged) cut-based dilepton trigger (double fake lines) | 0.69 +/- 0.13 | 0.69 +/- 0.13 |
!2747 (merged) cut-based dilepton trigger (total) | 5.72 +/- 0.38 | 5.56 +/- 0.38 |
Master MVA-based dilepton trigger (total) | 8.67 +/- 0.47 | 8.46 +/- 0.47 |
Master b-topological trigger (total) | 27.77 +/- 0.84 | 26.98 +/- 0.83 |
Conclusion: the rate sits at ~2/3 that of the MVA-based dilepton trigger.
Important note: the increase in rate with respect to the cut-based dilepton trigger in master is not because this retuning has a higher-than-intended rate, instead it is due to the rate of the cut-based dilepton trigger in master being significantly lower than anticipated upon initial merge (O(1 kHz)).