Draft: New bdt-based HLT2 line for tau-> mu gamma
(Implemented in !3157 (merged))
New BDT-based HLT2 line for tau-> mu gamma. The MVA cut > 0.5 helps to keep the rate at 10 Hz as in !3012 (merged).
This line is also meant to be saved in TURBO.
Running over 100K minbias events:
Rate
--------------------------------------------------------------------------------------------------------------
INFO: Starting /user/gr1/lhcb/cocha/stack_tau_mugamma/DaVinci/HltEfficiencyChecker/scripts/hlt_calculate_rates.py...
--------------------------------------------------------------------------------------------------------------
INFO: No lines specified. Defaulting to all...
HLT rates:
--------------------------------------------------------------------------------------------------------------
Line: Hlt2RD_TauToMuGamma_EE_MVADecision Incl: 0.057 +/- 0.0254 kHz, Excl: 0.0 +/- 0.0 kHz
--------------------------------------------------------------------------------------------------------------
Hlt2 Total: Rate: 0 +/- 0.0 kHz
--------------------------------------------------------------------------------------------------------------
Bandwidth, running over 100K minbias events:
event rate x event size = (57 Hz) x (21 Kb) = ~ 1.197 Mb/s
Efficiency estimate, running over 100k signal events: 5.486 %
PD. Needs lhcb-datapkg/ParamFiles!82 (merged)
Edited by Miguel Ramos Pernas