Skip to content

Draft: New bdt-based HLT2 line for tau-> mu gamma

Carlos Eduardo Cocha Toapaxi requested to merge cocha/tau_mugamma_mva into master

(Implemented in !3157 (merged))

New BDT-based HLT2 line for tau-> mu gamma. The MVA cut > 0.5 helps to keep the rate at 10 Hz as in !3012 (merged).

This line is also meant to be saved in TURBO.

Running over 100K minbias events:

Rate

--------------------------------------------------------------------------------------------------------------
INFO:    Starting /user/gr1/lhcb/cocha/stack_tau_mugamma/DaVinci/HltEfficiencyChecker/scripts/hlt_calculate_rates.py...
--------------------------------------------------------------------------------------------------------------
INFO:    No lines specified. Defaulting to all...
HLT rates: 
--------------------------------------------------------------------------------------------------------------
Line:    Hlt2RD_TauToMuGamma_EE_MVADecision      Incl: 0.057 +/- 0.0254 kHz,    Excl: 0.0 +/- 0.0 kHz
--------------------------------------------------------------------------------------------------------------
Hlt2 Total:                                    Rate:     0 +/- 0.0 kHz
--------------------------------------------------------------------------------------------------------------

Bandwidth, running over 100K minbias events:

event rate x event size = (57 Hz) x (21 Kb) = ~ 1.197 Mb/s

Efficiency estimate, running over 100k signal events: 5.486 %

PD. Needs lhcb-datapkg/ParamFiles!82 (merged)

Edited by Miguel Ramos Pernas

Merge request reports

Loading