Restore 2017 settings for Moore_RateTest.py
The following tests FAILED:
11 - Moore.mooreratetest.efficiencies.efficiency (Failed)
14 - Moore.mooreratetest.rates.from_settings_splithlt1 (Failed)
15 - Moore.mooreratetest.rates.from_settings_splithlt2 (Failed)
17 - Moore.mooreratetest.rates.from_tck_splithlt1 (Failed)
18 - Moore.mooreratetest.rates.from_tck_splithlt2 (Failed)
Due to ImportError: No module named Physics_pp_2018
. This was caused by the change in default settings in Moore-RateTest.py
introduced in lhcb-datapkg/PRConfig@a14b97bc.
This MR restores the 2017 settings in the 5 failing tests. It fixes two of the tests, the others now fail elsewhere in the Moore-RateTest.py
script, presumably due to some other backward incompatibility introduced in PRConfig