Update of muon showers line after retraining the BDT with HLT1_filtered data
Retraining of the BDT for the muon detector showers line Hlt2QEE_MDS_BDT_nHits with HLT1 filtered data to solve MC/data differences.
We tried to maintain reasonable bandwidth levels without the current prescale of the Hlt2QEE_MDS_BDT_nHits line (0.01) with two distinct processing lines:
- Full-stream – for background studies (a higher cut on the BDT was imposed).
- Turbo – to ensure signal retention if the full-stream cut is too high.
This merge request is associated with the approval of Update of muon-showers weights, which updates the BDT weights after retraining with HLT1-filtered data.
BANDWIDTH TESTS:
We conducted the QEE bandwidth test using 10.000 HLT1-filtered events for the following branches:
-
qee_upgrade (old muon_showers line with a 0.01 prescale)
- Turbo bandwidth: 191.952 MB - Full-stream bandwidth: 516.516 MB - Rate: 516.0 kHz
-
muon_showers (new Turbo and full-stream lines with no prescale):
- Turbo bandwidth: 158.412 MB - Full-stream bandwidth: 523.74 MB - Turbo rate: 258.0 kHz - Full-stream rate: 129.0 kHz
Merge request reports
Activity
mentioned in merge request lhcb-datapkg/ParamFiles!135 (merged)
- Resolved by Ross John Hunter
@rjhunter this supersedes !4582 (closed). Requested review to the DPA/RTA QEE liaisons.
- Resolved by Pasquale Andreola
- Resolved by Pasquale Andreola
- Resolved by Pasquale Andreola
- Resolved by Pasquale Andreola
- Resolved by Pasquale Andreola
- Resolved by Pasquale Andreola
added 1 commit
- 7a3207c5 - Corrected import locations and some redundancies in configs
- Resolved by Andrii Usachov
- Resolved by Ross John Hunter
The full line needs a sprucing line in order for output to be written to disk, do you plan to add that now, or for EoY sprucing?
I think the BW estimates are a bit off compared to what I get (I am getting about 575 MB/s for qee_upgrade branch), are you remembering to compress the mdf file first?
mentioned in merge request !4367 (merged)
- Resolved by Carlos Vazquez Sierra
added 46 commits
-
ab6adc5e...f7b83213 - 42 commits from branch
qee_upgrade
- 4f8a1040 - Update of muon showers line after retraining the BDT with HLT1_filtered data
- 1ef45562 - pre-commit fixes
- ad929c4c - Corrected import locations and some redundancies in configs
- 2054f328 - pre-commit fixes
Toggle commit list-
ab6adc5e...f7b83213 - 42 commits from branch
- Resolved by Ross John Hunter
Thanks very much for addressing comments so far.
Code looks good to me, just one comment on it for curiosity: why did you remove the monitoring from the turbo line and just have it on the full-stream line?
Bandwidth changes are fine.
- Resolved by Ross John Hunter
added 1 commit
- 5f060280 - Redid small changes in import locations and configs
mentioned in issue #939
- Resolved by Carlos Vazquez Sierra
@amartin6 @mariape @cvazquez @jcidvida since the QEE deadline has passed I want to move on here. The code looks good, and the bandwidth change you report here is fine.
Please please make a study of the robustness of this with data-taking conditions and add it to #939 by the end of next Tuesday so we have some time to react before
qee_upgrade
gets merged tomaster
.This can be merged now, I'll allow one of you to push the "merge" button.
mentioned in commit e50ab1e8