Update of muon showers line after retraining the BDT with HLT1_filtered data
Compare changes
Files
2@@ -41,6 +41,7 @@ full_lines.update(high_mass_dielec.all_lines)
@@ -52,6 +53,6 @@ turbo_lines.update(drellyan.all_lines)
Retraining of the BDT for the muon detector showers line Hlt2QEE_MDS_BDT_nHits with HLT1 filtered data to solve MC/data differences.
We tried to maintain reasonable bandwidth levels without the current prescale of the Hlt2QEE_MDS_BDT_nHits line (0.01) with two distinct processing lines:
This merge request is associated with the approval of Update of muon-showers weights, which updates the BDT weights after retraining with HLT1-filtered data.
BANDWIDTH TESTS:
We conducted the QEE bandwidth test using 10.000 HLT1-filtered events for the following branches:
qee_upgrade (old muon_showers line with a 0.01 prescale)
- Turbo bandwidth: 191.952 MB
- Full-stream bandwidth: 516.516 MB
- Rate: 516.0 kHz
muon_showers (new Turbo and full-stream lines with no prescale):
- Turbo bandwidth: 158.412 MB
- Full-stream bandwidth: 523.74 MB
- Turbo rate: 258.0 kHz
- Full-stream rate: 129.0 kHz