RD add inclusive X ee with LL , LU, UU pairs and single L track with MedianDEDX cut
Line is developed from Stripping Bu2LLK
but running the di-electron maker on
- long + upstream + downstream tracks and vetoing the down-down category. An additional line is made with just the leptons pairs in full DST to allow further analysis possible
Additionally a single-electron long track selected using the MEDIANDEDX is used as well.
- long tracks single track with MEDIANDEDX also included.
All tracks which are supposed to have a Velo segment are also cut for the MEDIANDEDX
-
Di-Electron skelethon in place with RICH PID cuts and CALO PID cuts on (Up and Long) -
Mirrored cuts and stripping lines from Bu2LLK for B2eeX with m(ee) cut for conversion. -
Inclusive gamma->ee displaced from LL, LU, UU pairs adding the MedianDEDX cut on the velo segment of tracks -
Di-Hadron makers to recheck -
Single electron Long with MEDIAN_DEDX cut on top? -
Skelethon for the Isolation variable in place as well as the SS of lepton part -
More decays with displaced di-electron covered by di-electron [need post-combine particles in BHadronCompleteEvent]
FYI @clangenb
The rate obtained now are the following. @chefdevi the Long-Downstream category is also included now where the LONG is cutted for the MEDIANDEDX, tough for the Rate control Down-Down is not included After discussion with some Run2 reconstruction experts, it makes sense to see long-downstream converted photon due to a combination of clone killing and pattern recognition logics reducing the performance when velo hits are overlapping.
- Long/Down pair is now cut for 100 MeV mass window to boost efficiencies according to MC studies.
We are currently testing the lines over K*gamma simulation recently produced with SplitSim. So far we don't see issue in merging the line With !1853 (merged) merged ,
StrippingReport INFO Event 100000, Good event 100000
| *Decision name*|*Rate,%*|*Accepted*| *Mult*|*ms/evt*|
|_StrippingGlobal_ | 0.8460| 846| | 8.718|
|_StrippingSequenceStreamLeptonic_ | 0.6170| 617| | 7.176|
|!StrippingHb2XGammaConverted_b2xsingleconversionsLine | 0.6170| 617| 3.668| 6.428|
|!StrippingHb2XGammaConverted_b2xsingleconversionsLine_TIMING | 0.6170| 617| 3.668| 0.055|
|_StrippingSequenceStreamBhadronCompleteEvent_ | 0.2720| 272| | 1.318|
|!StrippingHb2XGammaConverted_ee_LL_anyconvertedLine | 0.1220| 122| 1.025| 0.754|
|!StrippingHb2XGammaConverted_ee_LD_anyconvertedLine | 0.0230| 23| 1.000| 0.031|
|!StrippingHb2XGammaConverted_ee_UU_anyconvertedLine | 0.0000| 0| 0.000| 0.025|
|!StrippingHb2XGammaConverted_ee_LU_anyconvertedLine | 0.1030| 103| 1.019| 0.026|
|!StrippingHb2XGammaConverted_ee_UD_anyconvertedLine | 0.0000| 0| 0.000| 0.024|
|!StrippingHb2XGammaConverted_eeLine | 0.0770| 77| 3.675| 0.070|
|!StrippingHb2XGammaConverted_eeSSLine | 0.0250| 25| 3.520| 0.059|
|!StrippingHb2XGammaConverted_ee_LL_anyconvertedLine_TIMING | 0.1220| 122| 1.025| 0.027|
|!StrippingHb2XGammaConverted_ee_LD_anyconvertedLine_TIMING | 0.0230| 23| 1.000| 0.022|
|!StrippingHb2XGammaConverted_ee_UU_anyconvertedLine_TIMING | 0.0000| 0| 0.000| 0.024|
|!StrippingHb2XGammaConverted_ee_LU_anyconvertedLine_TIMING | 0.1030| 103| 1.019| 0.021|
|!StrippingHb2XGammaConverted_ee_UD_anyconvertedLine_TIMING | 0.0000| 0| 0.000| 0.026|
|!StrippingHb2XGammaConverted_eeLine_TIMING | 0.0770| 77| 3.675| 0.064|
|!StrippingHb2XGammaConverted_eeSSLine_TIMING | 0.0250| 25| 3.520| 0.037|
The lines added in Leptonic
stream are :
-
StrippingHb2XGammaConverted_b2xsingleconversionsLine
:- single-long track with MEDIANDEDX cut combined to a set of 1-hadron,2-hadron,3-hadrons, one electron is lost, but recoverable with HOP mass tricks or tools Christoph developed.
The lines added in BHadronCompleteEvent
stream are :
-
StrippingHb2XGammaConverted_eeLine
:- 1-2,3 hadrons combined to a DiElectron made by
LL, LU, UU, DD, LD
pairing where for Long and Upstream a MEDIANDEDX cut is applied. Upstream tracks are cut for 0-pT as they aim to pick up soft conversions
- 1-2,3 hadrons combined to a DiElectron made by
-
StrippingHb2XGammaConverted_eeSSLine
:- same as above but with same sign electrons
-
StrippingHb2XGammaConverted_ee_{LL,LD,UU,LU,UD}_anyconvertedLine
:- inclusive di-electorn pair filtered as
StrippingHb2XGammaConverted_eeLine
which can be used afterwards in CombineParticles for any decay [ could be used for pi0 reconstruction for example ]
- inclusive di-electorn pair filtered as