Update of StrippingBs2JpsieePhi for EoY stripping.
- Increase the width of mass windows to have better left side-band
- Adjust the order of cuts to reduce timing.
The rate and timing looks fine:
StrippingReport INFO Event 10000, Good event 8816
| *Decision name*|*Rate,%*|*Accepted*| *Mult*|*ms/evt*|
|_StrippingGlobal_ | 0.3630| 32| | 13.383|
|_StrippingSequenceStreamLeptonic_ | 0.3630| 32| | 13.237|
|!StrippingBetaSBs2JpsieePhiDetachedLine | 0.2155| 19| 1.474| 10.719|
|!StrippingBetaSBs2JpsieePhiFromTracksLine | 0.2042| 18| 1.500| 1.054|
|!StrippingBetaSBs2JpsieePhiLine | 0.0794| 7| 2.571| 0.021|
|!StrippingBetaSBs2JpsieePhiDetachedLine_TIMING | 0.2155| 19| 1.474| 0.021|
|!StrippingBetaSBs2JpsieePhiFromTracksLine_TIMING | 0.2042| 18| 1.500| 0.021|
|!StrippingBetaSBs2JpsieePhiLine_TIMING | 0.1021| 9| 1.222| 0.014|