Skip to content
Snippets Groups Projects
Commit 8211a1d7 authored by Walter Lampl's avatar Walter Lampl Committed by Graeme Stewart
Browse files

load HVScaleCorr independent of larCondFlags.LoadElecCalib (LArConditionsCommon-00-02-71)

	  - For run 2, always load /LAR/ElecCalibFlat/HVScaleCorr because it's nowadays also needed by
	    the CaloNoiseToolDB (to rescale the noise automatically)
	  - This fixed bug ATLASRECTS-2101
	* tag  LArConditionsCommon-00-02-71

2015-03-13 Walter Lampl <walter.lampl@ cern.ch>
parent 91e225f6
No related branches found
No related tags found
No related merge requests found
......@@ -47,15 +47,35 @@ rekeyBC="<key>/LAR/BadChannels/BadChannels</key>"
rekeyMF="<key>/LAR/BadChannels/MissingFEBs</key>"
conddb.addFolderSplitOnline("LAR","/LAR/BadChannels/BadChannels","/LAR/BadChannelsOfl/BadChannels"+forceRN+rekeyBC)
conddb.addFolderSplitOnline("LAR","/LAR/BadChannels/MissingFEBs","/LAR/BadChannelsOfl/MissingFEBs"+forceRN+rekeyMF)
if not larCondFlags.LoadElecCalib.is_locked():
larCondFlags.LoadElecCalib.set_Value(rec.readRDO())
#For run 2 we use cool-inline storage in online database COOLONL_LAR/CONDBR2:
haveElecCalibInline=(conddb.dbdata=="CONDBR2")
if (haveElecCalibInline):
# Run 2 case:
#This service creates a objects in the DetectorStore that wrap the AttributeListCollections
#with the inline representation of the electronic calibration and makes them accessible through the
#ILArRamp, ILArOFC, etc. abstract interfaces
from LArRecUtils.LArRecUtilsConf import LArFlatConditionSvc
theLArCondSvc=LArFlatConditionSvc()
svcMgr+=theLArCondSvc
svcMgr.ProxyProviderSvc.ProviderNames += [ "LArFlatConditionSvc" ]
#Load HVScaleCorr. For run 2,these constants are also used by the CaloNoiseToolDB
if (haveElecCalibInline):
conddb.addFolder(ONLDB,"/LAR/ElecCalibFlat/HVScaleCorr"+forceRN+sqlDB)
theLArCondSvc.HVScaleCorrInput="/LAR/ElecCalibFlat/HVScaleCorr"
#Load Electronic Calibration folders:
if larCondFlags.LoadElecCalib():
#For run 2 we use cool-inline storage in online database COOLONL_LAR/CONDBR2:
haveElecCalibInline=(conddb.dbdata=="CONDBR2")
#Some examples based on ExtendedFTGrouping, not duely tested.
#Always use correction channels
......@@ -69,17 +89,8 @@ if larCondFlags.LoadElecCalib():
pass
if (haveElecCalibInline): # Run 2 case:
#This service creates a objects in the DetectorStore that wrap the AttributeListCollections
#with the inline representation of the electronic calibration and makes them accessible through the
#ILArRamp, ILArOFC, etc. abstract interfaces
from LArRecUtils.LArRecUtilsConf import LArFlatConditionSvc
theLArCondSvc=LArFlatConditionSvc()
svcMgr+=theLArCondSvc
svcMgr.ProxyProviderSvc.ProviderNames += [ "LArFlatConditionSvc" ]
if (haveElecCalibInline):
# Run 2 case:
#1. uA2MeV
if larCondFlags.ua2MeVFolder()=="":
conddb.addFolder("LAR_ONL","/LAR/ElecCalibFlat/uA2MeV"+forceRN)
......@@ -111,9 +122,9 @@ if larCondFlags.LoadElecCalib():
conddb.addFolder("LAR_OFL","/LAR/ElecCalibOfl/"+larCondFlags.MphysOverMcalFolder()+forceRN+sqlDB)
pass
#6. HVScaleCorr
conddb.addFolder(ONLDB,"/LAR/ElecCalibFlat/HVScaleCorr"+forceRN+sqlDB)
theLArCondSvc.HVScaleCorrInput="/LAR/ElecCalibFlat/HVScaleCorr"
#6. HVScaleCorr -> moved outside of the if loadElecCalib clause b/c it's now used by the CaloNoiseTool
#conddb.addFolder(ONLDB,"/LAR/ElecCalibFlat/HVScaleCorr"+forceRN+sqlDB)
#theLArCondSvc.HVScaleCorrInput="/LAR/ElecCalibFlat/HVScaleCorr"
#7. OFCs
if larCondFlags.OFCShapeFolder()=="":
......@@ -175,7 +186,7 @@ if larCondFlags.LoadElecCalib():
conddb.addFolder("LAR_OFL","/LAR/ElecCalibOfl/"+larCondFlags.MphysOverMcalFolder()+forceRN)
pass
#6. HVScaleCorr
#6. HVScaleCorr
conddb.addFolder("LAR_ONL","/LAR/ElecCalibOnl/HVScaleCorr"+forceRN)
#7. OFCs
......
0% Loading or .