T8 strength

Eliott Philippe Johnson requested to merge t8_strength into 2021

Changed the strengths in T8 for protons:

  • Strengths are now calculated using the full transfer function curve instead of a single point. (MCBs are very non-linear at high currents).

Changed dipole strength in dump line from -540 A to -520 A as seen on this logbook entry: https://logbook.cern.ch/elogbook-server/GET/showEventInLogbook/3526120

Merge request reports