Adapting CorryvreckanWriterModule to have time_resolution parameter for all detectors
The parameter time_resolution
has been added to the output Corryvreckan
geometry file.
A hard-coded value of 5ns
is used for all detectors due to the time structure of written out events: events of length 5ns, with a gap of 10ns in between events.