Fix metrology
@mtogawa reviewed the latest quad_module_metrology
analysis cuts and commented:
I also check CAD drawings and y direction looks wrong. y-distance of 0.65 looks btw alignment mark on PCB and first bond pad. Alignment mark on ASIC should be +0.1. Then, Criteria should be 750+-100, [650,850].
Also it was observed the formatting is incompatible with the PDB test run:
The following details may help:
{
"uuAppErrorMap": {
"ucl-itkpd-main/uploadTestRunResults/invalidParametersDtoIn": {
"id": "80893d9cadd45d9c422c12b039040fcd",
"timestamp": "2025-02-26T23:07:41.374Z",
"type": "error",
"message": "Parameters DtoIn is not valid.",
"paramMap": {
"invalidValueKeyMap": {
"$": {
"shape.e002": "The content of shape must be valid."
}
},
"invalidTypeKeyMap": {
"$.STD_DEVIATION_THICKNESS": {
"array.e001": "The value must be array."
}
}
}
},
"cern-itkpd-main/validatePropertiesHelper/unsupportedProperties": {
"type": "warning",
"message": "DtoIn contains unsupported keys.",
"paramMap": {
"unsupportedKeyList": [
"$.MEASUREMENT_VERSION",
"$.QC_LAYER",
"$.INSTITUTION"
]
}
}
}
}
This MR will fix these points.