LAr Calorimeter Signal FeedThroughs detailed geometry implemented.
LAr Calorimeter Signal FeedThroughs detailed geometry implemented (ATLASSIM-4437).
LAr Calo dead material description was simplified for the Barrel and EC FeedThroughs and Front-End Crates.
The introduced changes are:
- Detailed description for each Signal FT, including corresponding materials.
- Extra structures for Endcap FTs (cables, chimneys).
- Endcap FEC size and position fixes.
To activate, one has to set
from LArGeoAlgsNV.LArGeoAlgsNVConf import LArDetectorToolNV
LArDetectorToolNV.ActivateFeedThrougs=True
Otherwise, the earlier behavior remains.
The patch contains slight change of CALO and Muon envelope volumes (a 12 mm Z plane shift at the back of the calorimeter), and this may affect other systems. Overlap check with ROOT shows no clashes.
Edited by Andrei Sukharev