Skip to content

sTGC charge

Dylan Pizzi requested to merge dpizzi/athena:sTGC_Charge into 21.3

Implementing an improved energy to charge description and converting that charge to actual detector response of PDO counts. A more detailed model is coming soon and this is only the preliminary working set of changes. This full conversion will be moved to a calibration tool in the future.

The conversion from energy to charge was determined using average values from Garfield studies, the charge to mV and mV to PDO conversions were from VMM configurations for cosmic studies. Also, the VMM main threshold was changed due to the charge scaling being affected in the conversion.

@alaurier @pscholer

Edited by Dylan Pizzi