Skip to content

Draft: Change MuonCombinedTrackFitter to use GX2 fitter instead of iPatFitter.

The hope is that it will improve the reproducibility.

Before you can difference with the second Muon with 1/8 threads:

-bash-4.2$ grep "Muon,  pt" out1.log 
#####   Muon,  pt : 2216.89 eta : 1.59942 phi : 0.75371 mass : 105.658 author 4 type : 2 secondary authors: 
#####   Muon,  pt : 3214.67 eta : 1.33373 phi : 1.56512 mass : 105.658 author 6 type : 0 secondary authors:  4
-bash-4.2$ grep "Muon,  pt" out8.log 
#####   Muon,  pt : 2216.89 eta : 1.59942 phi : 0.75371 mass : 105.658 author 4 type : 2 secondary authors: 
#####   Muon,  pt : 3212.1 eta : 1.33373 phi : 1.56515 mass : 105.658 author 6 type : 0 secondary authors:  4

After the change the second muon is different pT again (which isn’t ideal), but is apparently stable.

-bash-4.2$ grep "Muon,  pt" out1_GC2.txt 
#####   Muon,  pt : 2216.89 eta : 1.59942 phi : 0.75371 mass : 105.658 author 4 type : 2 secondary authors: 
#####   Muon,  pt : 3323.64 eta : 1.33368 phi : 1.56384 mass : 105.658 author 1 type : 0 secondary authors:  4 6
-bash-4.2$ grep "Muon,  pt" out8_GC2.txt 
#####   Muon,  pt : 2216.89 eta : 1.59942 phi : 0.75371 mass : 105.658 author 4 type : 2 secondary authors: 
#####   Muon,  pt : 3323.64 eta : 1.33368 phi : 1.56384 mass : 105.658 author 1 type : 0 secondary authors:  4 6
Edited by Edward Moyse

Merge request reports