New eta- and mu-dependent TRT conversion track cuts

This MR is a re-tune of the TRT photon conversion tracks:

  • Cuts implemented in the InDetTrtTrackScoringTool, during Standalone TRT track selection:
    • The precision hit fraction for standalone TRT tracks is relaxed from 0.3 to 0.15
    • New eta- and mu-dependent cuts on nTRT for TRT tracks
  • Cuts implemented in InDetConversionTrackSelectorTool:
    • New eta-dependent cuts on eProbabilityHT are introduced for TRT tracks
  • Cut values for this and related cuts are changed (based on conditions tag OFLCOND-MC16-SDR-RUN2-04)

In addition, more comments are added to the code, and the code logic in InDetConversionTrackSelectorTool.cxx is re-arranged to improve readability.

Presentations :

JIRA tickets

Edited by Christos Anastopoulos