Closed
Created Oct 15, 2021 by Joao Victor Da Fonseca Pinto@jodafonsDeveloper
  • Report abuse
Report abuse

Draft: Apply the right calibration at precision calo step

  • Overview 4
  • Commits 2
  • Changes 8

This MR is a part of !46701 (closed) (from @dbakshig). Since the egammaSuperCluster is in place, we need to specify the calibration MVA at the precision calo step. Here, we setup the Rel21 calib folder (as suggested by offline people) and adapt the precision calo sequence to specify if is an electron or photon sequence. We need to specify this now because of the SuperCluster calibration type (Use electron or photon Tools) implemented here (!47201 (merged)).

To validate this, we launched two productions based on 14th round:

  • Current sequence in master (egammaTopo): https://bigpanda.cern.ch/task/27078455/
  • This MR (egammaSuper + Rel21 calibration): https://bigpanda.cern.ch/task/27078481/

We also have ATR-24180

Ping: @cjmeyer , @dbakshig , @fernando , @christos , @safarzad, @aranzazu , @tamartin

Edited Oct 15, 2021 by Joao Victor Da Fonseca Pinto
Assignee
Assign to
Reviewer
Request review from
Time tracking
Source branch: precision_calo_with_rel21_calibration