Skip to content

GitLab

  • Menu
Projects Groups Snippets
    • Loading...
  • Help
    • Help
    • Support
    • Community forum
    • Submit feedback
  • Sign in
  • athena athena
  • Project information
    • Project information
    • Activity
    • Labels
    • Members
  • Repository
    • Repository
    • Files
    • Commits
    • Branches
    • Tags
    • Contributors
    • Graph
    • Compare
    • Locked Files
  • Jira
    • Jira
  • Merge requests 189
    • Merge requests 189
  • Deployments
    • Deployments
    • Releases
  • Packages & Registries
    • Packages & Registries
    • Container Registry
  • Analytics
    • Analytics
    • Value stream
    • Code review
    • Issue
    • Repository
  • Activity
  • Graph
  • Commits
Collapse sidebar
  • atlas
  • athenaathena
  • Merge requests
  • !49804

Merged
Created Jan 20, 2022 by Daniele Zanzi@dzanziDeveloper

new L1 json for electrical connectors (ATR-24799)

  • Overview 30
  • Commits 29
  • Pipelines 7
  • Changes 15

Implement flat bit index for the electrical cables to CTP, as requested by L1CT. More information given in ATR-24799. This affects the configuration of L1Topo and CTP FW and simulation.

In addition to this change there are few more fixes in the L1 menu configuration, including:

  • some udpates in Trigger/TrigConfiguration/TrigConfIO/utils/TestTriggerMenuAccess.cxx
  • fix a check for the L1Menu consistency
  • removal of the CTP monitoring items as these will be added later based on the available CTP resources
  • add prefix in the trigger lines of the merger
Edited Jan 31, 2022 by Daniele Zanzi
Assignee
Assign to
Reviewer
Request review from
Time tracking
Source branch: ATR-L1elCable_dzanzi