Draft: L1Topo: Fix coordinates for jFex inputs
Change the coordinate inputs for the jFex TOBs from globalEta() and globalPhi() to eta() and phi(), considering their respective conversion factors. The implementation follows the one already present for the muon inputs.
- eta() and phi() return floats of the geometrical coordinates of the trigger chambers
- L1Topo granularities are 0.025 for eta (=> inverse = 40) and 0.05 for phi (=> inverse = 20)
- L1Topo simulation uses positive phi (from 0 to 2pi) => transform phiTopo
Related to ATR-26402.