Tighten eTAU HM cuts [ATR-27067]
@hillier proposed to use 72 as the firmware value --> 0.1 as the rHad cut in the eTAU40HM, i.e. the only existing HM threshold in the L1 menu. This cut should be better for LLP identification.
Notes:
- This does not feed any HLT at present
- There is no impact on other
eTAUthresholds, which all cut onrCoreonly - Changing the
Mediumworking point foreTAUrCorerequires also changingTightsince !63922 (merged)