Implement AFP ToF delta z trigger
-
TrigAFPToFHypopackage-
GenericMonitoringToolfor monitoring vertex counts and vertex positions - Refine vertex handling when multiple vertices in AFP or ID
-
-
AFPMenuSequence- Add lines to collect histograms generated by the monitoring tool in the hypo package
- Set delta Z cut for
afpdz5andafpdz10as +- 5 or 10 mm
-
Add chains to the
Dev_pp_run3_v1andPhysicsP1_pp_lowMu_run3_v1menuHLT_2j20_ftf_mb_afprec_afpdz5_L1RD0_FILLED HLT_2j20_ftf_mb_afprec_afpdz10_L1RD0_FILLED- Need prescale
-
HLT_2j20_ftf_mb_afprec_afpdz10_L1RD0_FILLEDTests
- MC detector hits: successful run but low statistic (
10^1) AFP vertices over10^5events - RAW data: successful run but no AFP vertex due to outdated calibration parameters (can be updated via
CondDB) - `runTrigART`: OK after applying patch to trigger reference files
- MC detector hits: successful run but low statistic (
JIRA: https://its.cern.ch/jira/browse/ATR-15719, https://its.cern.ch/jira/browse/ATR-22255
Edited by Hanfei Cui