Tune Phase-2 muon eta hough transform
Retuning pass of the HT after running on data.
- improved pre-estimate of search range using approximate projection onto chamber center
- revised binning
- improved / bug-fixed accumulator filler methods
Brings down the eta hough CPU from ~40 to 7 ms per data event, further speed ups will be achieved on the ACTS side. Also improves maximum-finding and hit collection efficiencies as well as parameter resolutions.
CC @jojungge
Merge request reports
Activity
This merge request affects 4 packages:
- MuonSpectrometer/MuonPhaseII/MuonPatternRecognition/MuonPatternHelpers
- MuonSpectrometer/MuonPhaseII/MuonPatternRecognition/MuonPatternRecognitionAlgs
- MuonSpectrometer/MuonPhaseII/MuonPatternRecognition/MuonSpacePointFormation
- MuonSpectrometer/MuonPhaseII/MuonValidation/MuonPatternRecognitionTest
Affected files list will not be printed in this case
Adding @stavrop ,@pscholer ,@jojungge ,@rosati ,@kluit ,@apsallid as watchers
added MuonSpectrometer Upgrade main review-pending-level-1 labels
✅ CI Result SUCCESS (hash 0ad467c4)Athena externals ✅ cmake ✅ make ✅ tests ✅ Full details available on this CI monitor view. Check the JIRA CI status board for known problems
✅ Athena: number of compilation errors 0, warnings 0
📝 For experts only: Jenkins output [CI-MERGE-REQUEST-EL9 13740] (remote access info)added review-approved label
removed review-pending-level-1 label
mentioned in merge request !73396 (merged)
mentioned in commit 6b0020b8