updates to ZDC monitoring of injector pulse stream and in online environment
- for injector pulse, turned off RPD + centroid tools in reconstruction, and disabled aux-data reading, ntuple writing and histogram filling downstream
- updated configurations to progress towards reconstructing data from standalone tests
- restructured histogram paths: (1) side 0,1 --> side A,C (2) changed top path from /ZDC to /SHIFT and /EXPERT (3) changed per-arm observables from monitored under global monitoring tool to under per-arm (side) tool
- added new histograms - highlights: (1) reco amp versus input voltage histograms for injector pulse (2) for RPD DQ: channel + centroid valid-bit histograms; x,y centroid 1D distributions (3) RPD max sample + sum versus max ADC
- additional updates of monitoring: (1) added filterings for injector pulse versus calib streams (2) added filtering + adjusted LB-dependent histogram binnings for online environment (3) adjusted ranges/binnings (4) changed to using calib amplitudes for module fractions + require min energy (5) added calibration for online monitoring
- added reading of json file for determining pulser input voltage as function of LB + monitoring reco amplitude versus input amplitude
Marked urgent for ZDC commissioning, preparing for HI run. @steinber @bcole