Bug 1 related to the start signal in a pulser group (WREN gateware)
For this configuration (and similar configurations) it was noticed that when the start signal toggles with a period of 200ns, the first period of pulses is not generated correctly. For the same configuration, when the start signal toggles with a period of 20000ns, pulses are generated with the correct period. In both cases, the start signal starts toggling when the configuration is loaded into a pulser, and the pulser is in the state in which it waits for the start signal.
Pulser number: 1. Its configuration is
- repeat mode: 0
- start input: 0
- stop input: 31
- clock input: 31
- pulser output: 0
- initial delay [clk cycl]: 0
- pulse width [ns]: 24
- pulse period [clk cycl]: 46
- number of pulses: 4
- time [s]: 293
- time [ns]: 4354
For the configuration 1 the pulse period is not executed correctly.
Expected - 46, generated - 45