Use the new GBT configuration file format
Description
This MR aims at using the new GBT configuration files produced by cmsgemos-analysis!17 (merged).
Related Issue
How Has This Been Tested?
The complete GBT configuration sequence was successful for the 3 OptoHybrid of the GE1/1 integration setup:
- Copy the default GBT configuration and the bootstrap phase files
- Launch a GBT scan
- Analyze the output files with the tool provided in cmsgemos-analysis!17 (merged)
- Copy the updated GBT configuration files on the back-end board
- Launch a normal data-taking run
Types of changes
-
Bug fix (non-breaking change which fixes an issue) -
New feature (non-breaking change which adds functionality) -
Breaking change (fix or feature that would cause existing functionality to change)
Checklist:
-
My code follows the code style of this project. -
My change requires a change to the documentation. -
I have updated the documentation accordingly. -
I have read the CONTRIBUTING document. -
I have added tests to cover my changes. -
All new and existing tests passed.