Add the FED ID and slot number in the RunParams for Physics
Description
As said in the title, this MR adds the FED ID and slot number in the RunParams with the RunType is set to Physics.
Additionally, it fixes a bug introduced in !206 (merged) where the RunType couldn't be reset due to the absence of an "Apply" button.
The scan routines in the AMCManager
have as well been clean-up following the discovery of the TTC generator being disabled even if not desired.
Related Issue
How Has This Been Tested?
Tested successfully on the GE1/1 integration test stand in b904.
Types of changes
-
Bug fix (non-breaking change which fixes an issue) -
New feature (non-breaking change which adds functionality) -
Breaking change (fix or feature that would cause existing functionality to change)
Checklist:
-
My code follows the code style of this project. -
My change requires a change to the documentation. -
I have updated the documentation accordingly. -
I have read the CONTRIBUTING document. -
I have added tests to cover my changes. -
All new and existing tests passed.