Skip to content

Add GE1/1 VFAT FEAST voltage monitoring

Laurent Petre requested to merge feature/ge11-vfat-voltages into main

Description

The title should speak for itself.

Also includes various bug fixes or enhancements related to the SCA-based monitoring.

  • Ensure that the ADC conversions are over before retrieving the measurement, even in the case of an AXI bus error.
  • Make use of the 1kOhm precision resistor to calibrate the ADC current source (improve dramatically the PT100/PT1000 precision).
  • Export the raw ADC counts in the JSON monitorable object for debugging purposes.

Related Issue

None... 😕

How Has This Been Tested?

Thoroughly tested on the GE1/1 QC7 setup.

Types of changes

  • Bug fix (non-breaking change which fixes an issue)
  • New feature (non-breaking change which adds functionality)
  • Breaking change (fix or feature that would cause existing functionality to change)

Checklist:

  • My code follows the code style of this project.
  • My change requires a change to the documentation.
  • I have updated the documentation accordingly.
  • I have read the CONTRIBUTING document.
  • I have added tests to cover my changes.
  • All new and existing tests passed.
Edited by Laurent Petre

Merge request reports