To check the HV status during your shift, open the [GE2/1 HV dashboard](https://cmsgemonline-monitoring.app.cern.ch/d/d216e186-f0b5-4e81-b9f0-5cf3119bf76d/ge2-1-hv?orgId=1&refresh=1m). For each of the 5 detectors (GE2/1-M-16-L1 + each of the 4 modules of GE2/1-M-18-L1) you will see a list of panels showing:
> **Note:** if you see interrupted trends or "no data" warnings, you might need to increase the time range of the dashboard from the top right and see the history in the last 3 or 6 hours. This might happen because the detectors are very stable and the monitorables are not updated unless they are changing over time.
2. ~~Additionally, open the [rack monitoring dashboard](https://cmsgemonline-monitoring.app.cern.ch/d/Qg1GTdfVk/rack-monitoring?orgId=1&from=now-2d&to=now) and check the temperature trend of rack S1G13. If the temperature in the rack has risen over 23 °C in the last three hours, please call the run coordinator.~~ **This check is not needed any more**
**In any case**, please write an elog in the [GEM Commissioning section](https://cmsonline.cern.ch/webcenter/portal/cmsonline/pages_common/elog?__adfpwp_action_portlet=683379043&__adfpwp_backurl=https%3A%2F%2Fcmsonline.cern.ch%3A443%2Fwebcenter%2Fportal%2Fcmsonline%2Fpages_common%2Felog%3F_afrMFO%3D0%26_afrMFR%3D192%26_afrMFS%3D0%26_afrWindowMode%3D0%26_afrMFG%3D0%26_afrMFCI%3D0%26_afrMFH%3D729%26_afrMFM%3D0%26_afrMFDH%3D900%26_afrMFC%3D8%26_afrMT%3Dscreen%26_afrLoop%3D5229048267887324%26_afrFS%3D16%26_afrMFW%3D1440%26Adf-Window-Id%3Dw1d9sml9rcr%26_afrMFDW%3D1440%26__adfpwp_mode.683379043%3D1&_piref683379043.strutsAction=%2FviewSubcatMessages.do%3FcatId%3D1691%26subId%3D1715%26page%3D1) (Home > Subsystems > GEM > P5 > Commissioning) containing **the time you performed the check and the S1G13 temperature**.