Introduce central MMC tool config
BeamEnergy
was not configured so far (the default is 6.5 TeV https://gitlab.cern.ch/atlas/athena/-/blob/main/PhysicsAnalysis/TauID/DiTauMassTools/Root/MissingMassToolV2.cxx#L35 so good for Run 2 but not for Run 3).
Rather than updating every algorithm configuration, set up some central MMC tool config, with the BeamEnergy
set, imported for the relevant algorithms. Includes specific CalibSet=2016MC15C
for Analysis:bb𝝉𝝉
Checked to give identical outputs for Run 2 files.
FYI @mfujimot @shahzad @bmoser @pbokan @weiming @falves @gcallea