[A09] Readout
Please attach results and add address to corresponding json
GBTx config files:
/afs/cern.ch/user/n/nswdaq/public/sw/config-ttc/config-files/gbtx_config/191_sTGC_A09/config_gbtx1_LS.py
/afs/cern.ch/user/n/nswdaq/public/sw/config-ttc/config-files/gbtx_config/191_sTGC_A09/config_gbtx2_LS_flx8.py
OPC xml:
/afs/cern.ch/user/n/nswdaq/public/sw/config-ttc/config-files/opc_xml/191/A09/A09_STG_191_as_Large_Sector_FlxId8.xml
JSON:
-
Baselines
/afs/cern.ch/user/n/nswdaq/public/sw/config-ttc/config-files/config_json/191/A09/STGS_191_A09_baseline_flx8.json -
Pulser tests It has low level in pFEB_L3Q1_IP
/afs/cern.ch/user/n/nswdaq/public/sw/config-ttc/config-files/config_json/191/A09/STGC_191_A09_HOIP_TestPulse.json -
Trimmers
/afs/cern.ch/user/n/nswdaq/public/sw/config-ttc/config-files/config_json/191/A09/STGC_191_A09_HOIP_TestPulse.json -
Noise Runs -
[Nominal] https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_02_14h22m06s_191_noise/ -
[-10] https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_02_14h24m59s_191_noise/ -
[-20] https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_02_14h23m42s_191_noise/ -
[+10] https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_02_14h26m10s_191_noise/ -
[+20] https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_02_14h27m27s_191_noise/ -
[+30] https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_02_14h28m36s_191_noise/ -
Comparison Noise Runs: A09_comparison.pdf
-
-
Phase 2 https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_03_12h27m15s_191_phase2/
27/05/2021
-
(1) Baseline scan: https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_05_27_18h08m01s_191_baseline_summary/
L1DDC_L3_Q3_IPL over heating at largest colling flow, reaching 55 degree C. All other temperature monitoring look normal
28/05/2021
-
(1) Baseline scan trying to make up for the very low noise (~0.3 mv) from IP SFEB L3Q2 VMM7 by setting slg in the json file. No change has been seen: https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_05_28_14h15m24s_191_baseline_summary/
-
(2) Baseline scan after switching off the IP Q3 L1DDCs(lower side) to save the board from overheating, with A09 MM off: https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_05_28_17h22m43s_191_baseline_summary/
-
(3) Baseline scan as in (2) above with A09 MM on: https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_05_28_17h33m21s_191_baseline_summary/
31/05/2021
- (1) Baselines https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_05_31_09h07m31s_191_baseline_summary/
- (2) Pulsers https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_05_31_10h30m27s_191_pulser/
02/06/2021
- (1) Baselines https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_02_11h16m14s_191_baseline_summary/
- (2) Pulsers. It has low level in pFEB_L3Q1_IP https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_02_11h46m22s_191_pulser/
- (3) Trimmers: https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_02_12h09m43s_191_x30/
03/06/2021
-
(1) Baseline scan test: https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_03_14h25m38s_191_baseline_summary/
-
(2) Pulser test: https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_03_15h18m05s_191_pulser/
-
(3) Noise run with minus24 threshold: https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_03_15h40m04s_191_noise/
08/06/2021
- (1) Baseline scan check: https://stgc-trimmer.web.cern.ch/stgc-trimmer/2021_06_08_10h19m12s_191_baseline_summary/